Request a Quote
Sanitary Diaphragm Seal (HSA) | Haygor Skip to product content

HSA diaphragm seal · Hygienic process connections · Food, beverage & pharmaceutical

Sanitary Diaphragm Seal

Flush pressure isolation for sanitary piping systems and vessel connections.

The Haygor HSA pairs a flush diaphragm with Tri-Clamp, Cherry Burrell I-Line, Varivent, DIN 11851, SMS 1145, or tank-spud process connections. Select the connection, size, material, instrument interface, surface finish, and documentation around the actual product and cleaning process.

  • Six published sanitary connection families
  • 316/316L stainless steel or Alloy C-276
  • Electro-polish and material-certificate options
Haygor HSA sanitary diaphragm seal with flush corrugated diaphragm and hygienic process connection
Flush diaphragm · Hygienic interfaceSanitary pressure-instrument isolation
HSA series 1.5 in. · 4 in.
01Isolates the instrumentProcess media stays at the diaphragm
02Fits sanitary systemsClamp, union, threaded & spud options
03Supports hygienic selectionFlush process-facing diaphragm
04Adds documentation choicesElectro-polish and MTR options

Quick answer

What is a sanitary diaphragm seal?

A sanitary diaphragm seal is a pressure-isolation device designed for hygienic process connections. The process-facing diaphragm separates food, beverage, pharmaceutical, and other sanitary media from the pressure instrument while a sealed fill fluid transmits the pressure signal.

The HSA provides connection choices for clamp, union, threaded, and tank installations. Its flush diaphragm reduces the exposed process geometry at the measurement point, while the selected fitting, gasket, clamp, surface finish, material, and installation determine whether the completed assembly fits the plant's hygienic and cleaning requirements.

Hydraulic pressure transfer

How the HSA sanitary seal works

The HSA creates a process-facing sanitary interface while hydraulically transferring pressure to a compatible instrument.

  1. 1

    The sanitary connection joins the process

    The selected clamp, I-Line, Varivent, threaded union, SMS union, or tank spud mates to the plant connection.

  2. 2

    Process pressure acts on the diaphragm

    The flush metallic diaphragm deflects in response to pressure while separating the media from the instrument.

  3. 3

    Fill fluid transfers the pressure signal

    A sealed hydraulic fill carries the diaphragm movement to the attached instrument or remote capillary.

  4. 4

    The instrument measures without direct contact

    The gauge, transmitter, switch, or controller receives pressure while remaining isolated from the sanitary process media.

Application fit

Sanitary pressure isolation for clean-process systems

Haygor publishes the HSA for sanitary food, beverage, and pharmaceutical applications and for multiple hygienic piping and tank connection standards.

Where the HSA can fit

  • Food and beverage process lines
  • Dairy and liquid-product systems
  • Pharmaceutical and life-science equipment
  • Sanitary tanks and vessels
  • Skids using clamp, union, or threaded sanitary connections

Selection conditions to verify

  • Exact sanitary standard, nominal size, and mating dimensions
  • Product media, concentration, allergen or contamination controls
  • Cleaning method, chemistry, temperature, pressure, and exposure time
  • Wetted material, gasket, surface finish, drainage, and orientation
  • Instrument range, fill fluid, ambient conditions, and response needs

Common hygienic settings

Pressure measurement where cleanability and isolation matter

  • Food processing
  • Beverage
  • Dairy
  • Pharmaceutical
  • Biotech
  • Sanitary skids

Published configuration envelope

HSA connection families and size selections

The selections below summarize Haygor's published HSA ordering guide. The guide does not state one universal pressure or temperature rating for every sanitary configuration; confirm the completed assembly for the actual process and cleaning cycle.

A

Tri-Clamp

Published in 1.5, 2.0, 2.5, 3.0, and 4.0-inch selections.

B

Cherry Burrell I-Line

Published in 1.5, 2.0, 2.5, 3.0, and 4.0-inch selections.

D

Varivent

Published DN25 Type F and DN40 Type N selections.

E

DIN 11851 threaded

Published DN25, DN32, DN40, and DN50 selections.

F

SMS 1145 union nut

Published 1.5 and 2.0-inch selections.

C

Tank spud

Industry-standard spud with 2 or 6-inch extension selections.

Published HSA sanitary connection selections
CodeConnection typePublished selections
ATri-Clamp1.5, 2.0, 2.5, 3.0, 4.0 in.
BCherry Burrell I-Line1.5, 2.0, 2.5, 3.0, 4.0 in.
DVarivent connectionDN25 Type F; DN40 Type N
EDIN 11851 threaded connectionDN25, DN32, DN40, DN50
FSMS 1145 union nut1.5 and 2.0 in.
CIndustry-standard tank spud2 or 6 in. extension

Connection names identify the published Haygor ordering selections. Verify the exact standard revision, mating component dimensions, gasket, clamp or union, pressure-temperature capability, surface finish, and certificate scope before release.

Configure the complete sanitary assembly

Connection, material, finish, instrument, and documentation

The seal is one part of a hygienic pressure-measurement system. Specify the process connection and cleaning environment before finalizing the instrument and fill system.

Choose the connection

Identify Tri-Clamp, I-Line, Varivent, DIN 11851, SMS 1145, or tank spud, including the applicable nominal size and mating standard.

Choose wetted materials

Select 316/316L stainless steel or Alloy C-276 against the process product, cleaning chemistry, concentration, temperature, and exposure time.

Define finish and hardware

State surface-finish requirements, electro-polish option, gasket, clamp or union hardware, tank-spud material, and installation orientation.

Complete the instrument system

Define instrument model and range, weld or NPT connection, direct or remote mounting, capillary, fill fluid, response, and ambient conditions.

Published material and hardware choices

Match the HSA to the product and cleaning cycle

  • Body: 316/316L stainless steel or Alloy C-276
  • Diaphragm: 316L stainless steel or Alloy C-276
  • Lower weld spud: none/not required, 316/316L stainless steel, or Alloy C-276
  • Tank-spud gasket: ethylene propylene for Type C
  • Instrument connection: weld, 1/4 NPT, or 1/2 NPT
  • Options: stainless clamp for Type C, electro-polish, MTR package

The ordering guide lists no gasket supplied for Types A and B. Specify the mating gasket and clamp or union as part of the installation rather than assuming they are included.

Scope matters

Do not treat “sanitary” as a blanket certification claim

Haygor's published 2021 certificate identifies specific HSA A/B/C/D model combinations and the lower tank spud. DIN 11851 and SMS 1145 connection codes are catalog selections but are not named in the certificate model-designation line reviewed for this page. Verify renewed or current certification, the exact order code, plant standard, and installation requirements.

Published dimensional drawings

HSA Tri-Clamp, I-Line, and tank-spud dimensions

Dimensions are in inches and reproduce Haygor's published tables. The source tables do not list every catalog size; request order-specific dimensions where a size is omitted.

Haygor HSA Tri-Clamp sanitary seal dimensional drawing with A and B callouts
HSA-A Tri-ClampPublished table lists 1.5, 2.0, 3.0, and 4.0-inch dimensional rows.
Haygor HSA Cherry Burrell I-Line sanitary seal dimensional drawing with A B C and D callouts
HSA-B Cherry Burrell I-LinePublished table lists 1.5, 2.0, 3.0, and 4.0-inch dimensional rows.
Haygor HSA tank-spud sanitary seal and matching tank-spud dimensional drawing
HSA-C Tank SpudPublished 2-inch and 6-inch extension configurations.
Published HSA-A Tri-Clamp dimensions
SizeAB
1.5 in.1.98 in.2.05 in.
2.0 in.2.51 in.2.05 in.
3.0 in.3.57 in.2.05 in.
4.0 in.4.68 in.2.05 in.
Published HSA-B Cherry Burrell I-Line dimensions
SizeABCD
1.5 in.1.90 in.2.00 in.1.74 in.0.20 in.
2.0 in.1.90 in.2.64 in.2.24 in.0.26 in.
3.0 in.1.90 in.3.88 in.3.31 in.0.31 in.
4.0 in.1.90 in.4.88 in.4.30 in.0.31 in.
Published HSA-C tank-spud dimensions
Extension lengthAB
2 in.2.10 in.2.10 in.
6 in.6.10 in.6.10 in.

The published Tri-Clamp and I-Line dimension tables omit the cataloged 2.5-inch row. Confirm the current drawing and order-specific dimensions with Haygor before fabrication or replacement work.

Frequently asked questions

Sanitary diaphragm seal FAQ

These answers summarize Haygor's published HSA information and the certificate document hosted by Haygor. Final selection requires review of the sanitary connection, process, cleaning method, seal, instrument, fill system, and certificate scope.

Ask Haygor a technical question
What is a sanitary diaphragm seal?

A sanitary diaphragm seal isolates a pressure instrument from hygienic process media. Process pressure acts on a flush diaphragm, and a sealed fill fluid transfers that pressure to the instrument without allowing the process media to enter the gauge, transmitter, switch, or controller.

Which sanitary connection types are available for the Haygor HSA?

Haygor publishes Tri-Clamp, Cherry Burrell I-Line, Varivent, DIN 11851 threaded, SMS 1145 union-nut, and industry-standard tank-spud configurations. Connection availability depends on the selected type and size.

Which HSA sizes are published?

Published inch selections include 1.5, 2.0, 2.5, 3.0, and 4.0 inches for specified Tri-Clamp, I-Line, and SMS configurations. Haygor also lists Varivent DN25 and DN40 selections, DIN 11851 DN25 through DN50 selections, and an industry-standard tank-spud selection.

What tank-spud extension lengths are available?

The HSA ordering guide lists 2-inch and 6-inch extension lengths for Type C tank-spud seals. Confirm vessel geometry, weld-spud material, installation details, and the required insertion or stand-off before ordering.

Which instrument connections are available?

The HSA ordering guide lists a weld instrument connection, 1/4-inch NPT, and 1/2-inch NPT. The instrument, range, direct or remote mounting, capillary, and fill fluid should be selected as one pressure-measurement system.

Which body and diaphragm materials are published?

Haygor lists 316/316L stainless steel and Alloy C-276 for the HSA body, diaphragm, and optional lower weld-spud selections. Material compatibility must be reviewed against the actual product, cleaning chemistry, concentration, temperature, and exposure time.

Which HSA options are published?

Published options include a stainless-steel clamp for Type C tank-spud configurations, electro-polishing, and material certification with material test reports. Confirm the required surface finish, documentation, gasket, clamp, and connection standard in the final order.

What 3-A qualification documentation has Haygor published for the HSA?

Haygor hosts 3-A RPSCQC Certificate No. 71, initially issued June 7, 2021 and marked valid through December 31, 2021. It lists specified HSA A, B, C, and D model combinations and the lower tank spud. Treat it as published historical documentation and verify renewed or current certification, exact order-code scope, installation, and cleaning requirements with Haygor.

What information should I provide for an HSA quote?

Provide the sanitary connection standard and size, tank-spud length if applicable, process product and cleaning chemicals, operating and cleaning temperatures, operating and maximum pressure, instrument model and range, direct or remote mounting, wetted materials, surface-finish requirement, gasket and clamp requirements, fill-fluid constraints, and documentation or certification needs.

Move from sanitary connection data to an HSA configuration

Configure a sanitary diaphragm seal or send the complete hygienic application to Haygor.

Use the configurator for a guided starting point, or request a quote for connection standard, size, tank-spud length, wetted material, surface finish, gasket and hardware, instrument, fill fluid, cleaning conditions, and certificate review.