Request a Quote
Submersible Diaphragm Seal (HSU) | Haygor Skip to product content

HSU diaphragm seal · Immersed pressure sensing · Open or perforated cover

Submersible Diaphragm Seal

Immersed pressure isolation for tanks, pits, sumps, basins, and engineered hydrostatic level systems.

The Haygor HSU is configurable with 2.4-, 2.9-, or 4.1-inch diaphragms; 3.48-, 4.00-, or 5.40-inch standard outside diameters; open or perforated cover plates; and welded 8 mm, 1/4-inch NPT, G 1/4, or 1/2-inch NPT instrument connections.

  • Three diaphragm and outside-diameter envelopes
  • Open or perforated cover plate
  • 316 stainless steel configuration
Representative Haygor HSU Submersible diaphragm seal with perforated protective cover
Representative perforated-cover configurationImmersed pressure and hydrostatic head sensing
HSU series 3 diaphragm sizes
01Immersed sensing positionPlace the diaphragm at the selected liquid elevation
02Three standard size envelopes2.4, 2.9, or 4.1 in. diaphragm
03Cover plate choiceOpen or perforated process-facing protection
04Filled-system integrationWelded or female NPT instrument attachment

Quick answer

What is a submersible diaphragm seal?

A submersible diaphragm seal is an immersed pressure-sensing assembly. The seal is positioned below the liquid surface at the desired measurement elevation, where pressure acts on the process-facing diaphragm. A sealed fill fluid transfers that pressure to a gauge, transmitter, switch, or controller while isolating the instrument from the process liquid.

The HSU can be used as the process interface in an engineered hydrostatic level system or wherever a remote instrument needs to sense pressure at an immersed location. The cover style, diaphragm size, outside diameter, fill system, capillary, support method, and instrument range must be selected as one measurement assembly.

Immersed hydraulic pressure transfer

How the HSU seal works

The HSU places the diaphragm at the pressure-sensing elevation and transfers the signal through a sealed liquid-filled path.

  1. 1

    The seal is located at the measurement elevation

    The assembly is supported or suspended so its diaphragm senses pressure at a defined depth in the liquid.

  2. 2

    The cover admits process pressure

    An open or perforated cover allows liquid pressure to reach the diaphragm while matching the installation's exposure and protection needs.

  3. 3

    The diaphragm responds to local pressure

    The process-facing diaphragm deflects without allowing the process liquid into the instrument or fill passage.

  4. 4

    Fill fluid carries the signal to the instrument

    The attached instrument or remote capillary system converts the transferred pressure into pressure or level indication.

Application fit

Immersed pressure sensing where a conventional vessel nozzle is not the measurement point

The HSU is designed for installations that place the sensing diaphragm in the liquid itself. Application engineering should confirm that the media, solids, pressure, temperature, mounting, retrieval, and filled-system behavior are suitable.

Common application settings

  • Open tanks, basins, reservoirs, and process vessels
  • Sumps, pits, wet wells, and collection chambers
  • Hydrostatic head or inventory measurements in compatible services
  • Remote-mounted gauges or transmitters above the liquid
  • Water, wastewater, chemical, and industrial utility systems

Selection conditions to verify

  • Liquid chemistry, solids, fibers, deposits, and cleaning method
  • Density or specific gravity and expected composition changes
  • Operating, maximum, vacuum, and transient pressure
  • Process and ambient temperature plus fill-fluid limits
  • Support, retrieval, clearance, cable or capillary protection, and cover style

Typical industries and systems

  • Water & wastewater
  • Chemical processing
  • Industrial utilities
  • Bulk storage
  • Environmental systems
  • Process tanks
  • Pits & sumps

Current configurable envelope

HSU size, cover, connection, and construction selections

These selections summarize Haygor's current online HSU configurator. Confirm current availability and the completed filled-system pressure and temperature limits before release.

SIZE 2

2.4 in. diaphragm

3.48 in. standard outside diameter. Use /CD when a custom outside diameter is required.

SIZE 3

2.9 in. diaphragm

4.00 in. standard outside diameter. Balance sensitivity, clearance, and process conditions.

SIZE 4

4.1 in. diaphragm

5.40 in. standard outside diameter for the largest published HSU diaphragm envelope.

CONNECTION

W / 2 / 3 / 4

Welded 8 mm, 1/4-inch NPT, G 1/4, or 1/2-inch NPT instrument-side connection.

COVER STYLE

Open or perforated

The configurator lists open cover plate code C and perforated cover plate code P.

CONSTRUCTION

316 stainless steel

S6 is listed for upper, lower, diaphragm, and bolting; the bolting selection carries a 50% rating-reduction note.

HSU size and standard outside-diameter selections
Size codeDiaphragm diameterStandard outside diameterCustom diameter path
22.4 in.3.48 in.Add /CD and specify inches
32.9 in.4.00 in.Add /CD and specify inches
44.1 in.5.40 in.Add /CD and specify inches

Pressure-rating safeguard: the current HSU configurator does not state one universal maximum working pressure and notes that listed 316 stainless steel bolting reduces the applicable pressure rating by 50%. Use the lowest limit of the seal, bolting, instrument connection, instrument, capillary, fill fluid, temperature condition, and installation—and obtain Haygor's approved assembly rating.

Configuration guidance

Select the HSU as an immersed measurement system—not as an isolated component

Start with the diaphragm and outside-diameter envelope, then confirm cover style, instrument attachment, filled-system design, material compatibility, support, and retrieval.

Representative perforated cover plate for the HSU Submersible diaphragm seal
Code P

Perforated cover plate

A perforated plate provides a guarded process-facing surface while openings admit liquid pressure to the diaphragm.

Consider whenMechanical exposure or debris is a concernVerifyOpening area, solids, fouling, cleaning, response
Representative open cover plate for the HSU Submersible diaphragm seal
Code C

Open cover plate

An open cover presents the diaphragm with minimal obstruction for compatible, controlled immersed installations.

Consider whenDirect liquid exposure is acceptableVerifyImpact risk, solids, access, cleaning, support
Representative comparison of the three HSU Submersible diaphragm seal size envelopes
/CD option

Custom outside diameter

The standard outside diameter follows the selected diaphragm size. Add /CD and specify inches when the installation requires a different envelope.

Standard O.D.3.48, 4.00, or 5.40 in.VerifyClearance, support, cover, handling, retrieval

Instrument attachment

  • W: welded 8 mm connection
  • 2: 1/4-inch NPT
  • 3: G 1/4
  • 4: 1/2-inch NPT
  • Confirm direct versus remote mounting
  • Define capillary length, routing, armor, and support

The instrument, attachment, capillary, and fill fluid are part of the pressure-transfer system and must be reviewed together.

Current material selections

  • Upper: 316SS, code S6
  • Lower: 316SS, code S6
  • Diaphragm: 316SS, code S6
  • Bolting: 316SS, code S6
  • Verify corrosion, erosion, solids, and cleaning compatibility

The online configuration envelope may change. Confirm current alloy availability for the exact process and requested options.

Available options

  • /CD: custom outside diameter in inches
  • /AU: gold-plated diaphragm
  • /NS: PTFE-coated diaphragm, non-stick
  • Match option purpose to the actual failure mechanism
  • Confirm option compatibility with size and cover style

Treat /NS as a non-stick surface option, not as a substitute for corrosion-compatible base construction.

HSU configurable components and current online codes
ComponentCodeCurrent selectionEngineering check
Size22.4 in. diaphragm / 3.48 in. O.D.Range, sensitivity, clearance, solids
32.9 in. diaphragm / 4.00 in. O.D.Range, sensitivity, clearance, solids
44.1 in. diaphragm / 5.40 in. O.D.Range, sensitivity, clearance, solids
Instrument connectionWWelded 8 mmAttachment and fill method
21/4 in. NPTInstrument or capillary interface
3G 1/4Parallel-thread instrument or capillary interface
41/2 in. NPTInstrument or capillary interface
Cover styleCOpen cover plateImpact, solids, cleaning, access
PPerforated cover plateFouling, response, debris protection
ConstructionS6316SS upperMedia, temperature, erosion, rating, service life
S6316SS lower
S6316SS diaphragm
S6316SS bolting; current configurator notes 50% rating reduction
Options/CDCustom diameter, inchesPhysical fit and support
/AUGold-plated diaphragmApplication-specific barrier purpose
/NSPTFE-coated diaphragm, non-stickDeposit release; not corrosion protection

Configuration sequence

Build the HSU deliberately

1. Measurement basis
Pressure or hydrostatic level
2. Size
2.4, 2.9, or 4.1 in. diaphragm
3. Outside diameter
Standard O.D. or /CD custom value
4. Cover
Open C or perforated P
5. Connection
W, 2, 3, or 4
6. Construction/options
S6 materials plus /AU or /NS as needed
Start the HSU configurator

Information to confirm before release

  • Liquid, concentration, solids, density, and expected composition changes
  • Operating, maximum, transient, and vacuum pressure
  • Process and ambient temperature plus cleaning method
  • Measurement span, seal elevation, vessel reference pressure, and required accuracy
  • Open or perforated cover and required outside diameter
  • Instrument model, range, connection, mounting, capillary, and fill fluid
  • Support, suspension, retrieval, clearance, and mechanical protection
  • Required approved MWP, calibration, testing, and documentation

Compare process interfaces

Use the HSU when the diaphragm must sense pressure at an immersed location. Compare these designs when the process connection is threaded, mounted through a pipe wall, or uses a specialized flush interface.

Frequently asked questions

Submersible seal FAQ

These answers summarize the current HSU configurator and general filled-system engineering. Final selection requires review of the actual process, mounting, hydrostatic basis, and complete instrument assembly.

Ask Haygor a technical question
What is a submersible diaphragm seal?

A submersible diaphragm seal is positioned below the liquid surface so process pressure acts directly on its diaphragm. A sealed fill fluid transfers that pressure to a connected gauge, transmitter, switch, or remote instrument while isolating the instrument from the process liquid.

Can the HSU be used for hydrostatic level measurement?

It can be applied as the immersed pressure-sensing element in a properly engineered hydrostatic level system. Level accuracy depends on liquid density or specific gravity, vessel reference pressure, seal elevation, fill fluid, capillary routing, instrument range, and temperature effects.

Which HSU sizes are available?

Haygor's current configurator lists three size codes: Size 2 with a 2.4-inch diaphragm and 3.48-inch outside diameter, Size 3 with a 2.9-inch diaphragm and 4.00-inch outside diameter, and Size 4 with a 4.1-inch diaphragm and 5.40-inch outside diameter.

What is the difference between the open and perforated cover plates?

The open cover exposes the diaphragm face with minimal obstruction. The perforated cover places a protective plate over the diaphragm while openings admit process pressure. Select the cover based on solids, mechanical exposure, cleaning, response needs, and the installation environment.

Which instrument connections are listed for the HSU?

The current configurator lists a welded 8 mm connection under code W, 1/4-inch NPT under code 2, G 1/4 under code 3, and 1/2-inch NPT under code 4. Confirm the attachment, fill system, capillary, and instrument interface as a complete assembly.

Which materials are listed in the current HSU configurator?

The current configurator lists 316 stainless steel, code S6, for the upper, lower, diaphragm, and bolting selections. Final material suitability must be reviewed against the actual process chemistry, temperature, solids, cleaning method, and expected service life.

What is the pressure rating of the HSU?

A universal HSU pressure rating is not stated on the current configurator. The completed assembly must be reviewed for its lowest applicable limit, and the configurator specifically notes that its listed 316 stainless steel bolting reduces the applicable pressure rating by 50 percent. Obtain an approved maximum working pressure for the exact configuration.

What does the /CD option do?

The /CD option specifies a custom outside diameter in inches. Use it when installation clearance, protective hardware, support geometry, or an existing opening requires an outside diameter different from the standard 3.48-, 4.00-, or 5.40-inch envelope.

Is the /NS PTFE-coated diaphragm option corrosion protection?

No. Haygor identifies /NS as a non-stick PTFE-coated diaphragm option. Choose the base wetted material for chemical compatibility; do not treat the coating as a substitute for corrosion-resistant construction.

What should I provide for an HSU quote?

Provide the liquid and concentration, solids or debris, operating and maximum pressure, process and ambient temperature, liquid density or specific gravity, measurement span, seal elevation, cover style, required outside diameter, instrument model and range, connection, capillary length and routing, fill-fluid constraints, mounting or retrieval method, and documentation requirements.

Move from immersed measurement point to an HSU configuration

Configure a Submersible Seal or send the complete pressure or hydrostatic-level application to Haygor.

Use the configurator for a guided starting point, or request a quote with the liquid, solids, density, pressure, temperature, seal elevation, size, cover, outside diameter, instrument, capillary, fill fluid, mounting, retrieval, and documentation requirements.